Anogas has developed Hydrogel, a PFAS-free extinguishing agent designed to improve lithium-ion battery fire suppression through rapid cooling, gas control and thermal stabilisation
Lithium-ion batteries power smartphones, laptops, e-bikes and electric vehicles, while large energy storage systems support the transition to renewable energy. Their high energy density and long life make them highly effective, but they also introduce a fire risk that conventional extinguishing methods were not designed to manage.
Anogas, a Dutch materials innovation company with more than 20 years of experience in advanced materials, has developed Hydrogel as a sustainable response to this growing challenge. Made primarily from water and modified natural clay, the extinguishing agent is PFAS-free and designed to control the thermal, physical and chemical processes involved in lithium-ion battery fires.
Understanding lithium-ion battery fire risks
A lithium-ion battery fire is driven by reactions inside the battery rather than by an external fuel source alone. Mechanical damage, overheating, manufacturing defects or improper charging can destabilise an individual cell.
As its internal temperature rises, the cell may enter thermal runaway: an accelerating reaction that generates more heat, breaks down internal materials and releases flammable gases. Pressure builds until the casing ruptures.
The resulting heat can then spread to neighbouring cells, creating a cascading chain reaction. A small failure can therefore develop into a major incident within minutes. The gases released create an additional hazard. Hydrogen and methane can ignite or explode, while hydrogen fluoride is toxic and corrosive.
Gas release may continue even after visible flames have disappeared, leaving a risk of delayed ignition or re-ignition. Successful intervention therefore requires more than simply knocking down the flames.
The battery must be cooled, escaping gases must be controlled and the system must be stabilised.
How Hydrogel improves battery fire suppression
Hydrogel combines several extinguishing mechanisms in one material. Its high-water content absorbs heat rapidly and cools the battery at the source. Unlike water alone, however, Hydrogel becomes more viscous when exposed to high temperatures.
This temperature-sensitive response allows it to adhere to hot surfaces instead of flowing away. The resulting layer maintains contact with the battery and provides sustained cooling. It also forms a physical barrier that restricts oxygen, separates escaping gases from ignition sources and helps limit heat transfer to adjacent cells.
This is particularly important because residual heat and chemical activity can persist long after the visible fire has been extinguished. The modified clay particles add a further stabilising effect.
They can enter damaged battery structures and interact with reactive components, helping to reduce the reactions that sustain the incident.
At the same time, the water-and-clay-based barrier can reduce the concentration and ignition potential of hazardous gases. Together, these effects address the fire from several directions: cooling, containment, gas control and chemical stabilisation.
Controlling thermal runaway and preventing re-ignition
Thermal runaway can produce temperatures of approximately 1,500 degrees Celsius.
At these temperatures, extinguishing the visible flames is only the first stage. The objective is to bring the battery to a stable state without propagation or re-ignition. Hydrogel remains stable at these high temperatures, adheres to the affected surface and continues absorbing heat after the initial flame knockdown.
This prolonged action distinguishes comprehensive fire control from temporary suppression.
The technology can be applied through handheld extinguishers, mobile equipment and fixed water-based systems.
When deployed in expanded form, it can also cover larger surfaces, adhere to vertical structures and improve contact with difficult-to-reach areas. The amount required depends on the size and accessibility of the battery.
Small consumer devices may be addressed with a compact extinguisher, while e-bikes, power tools and larger battery systems require greater quantities. Industrial installations may need fixed or high-capacity delivery systems capable of applying Hydrogel from a safe distance.
Applying Hydrogel and managing post-fire safety
During an intervention, the initial focus should be on extinguishing all visible flames and preventing the fire from spreading.
Hydrogel should then be directed towards the battery surface and, where possible, into the internal structure to achieve localised cooling. Application can be repeated when new flames or gas emissions appear.
The situation should be monitored until no visible flames return and audible signs of gas release, such as hissing or sizzling, have stopped. Responders must still keep a safe distance and use appropriate respiratory protection.
Hydrogel can reduce atmospheric hazards, but it cannot remove every toxic gas produced by a failing battery. After stabilisation, an observation period of at least 20 minutes is recommended. The affected battery should subsequently be isolated from combustible materials and placed in a suitable containment or cooling arrangement.
Continued monitoring and a cooling period before disposal remain essential because damaged cells can retain energy and heat.
PFAS-free fire suppression and environmental performance
Many traditional firefighting foams have relied on PFAS to improve spreading and thermal stability. These substances are highly persistent, can contaminate soil and groundwater and are increasingly restricted.
European regulation is moving towards a complete phaseout of PFAS-containing firefighting agents, increasing demand for effective alternatives. Hydrogel contains no detectable PFAS and is based largely on water and natural clay.
This allows Anogas to combine operational performance with a lower environmental burden. Residual material can be collected, while suitable unused material may be separated and its clay-based fraction explored for reuse as a compost enhancer, supporting a more circular lifecycle.
NTA 8133 certification for lithium-ion battery fire extinguishers
Independent testing is essential when an extinguishing agent is intended for lithium-ion battery fires. Hydrogel extinguishers in 2-, 3-, 6- and 9-litre formats have been successfully tested and certified by Kiwa in accordance with NTA 8133.
This Dutch Technical Agreement provides a standardised method for evaluating portable fire extinguishers intended for lithium-ion batteries with a limited capacity of up to 600 Wh.
During the test, a 600 Wh arrangement of lithium-ion pouch cells is deliberately forced into thermal runaway. The operator must control the fire within the prescribed extinguishing period, after which the test is observed for 20 minutes.
No sustained re-ignition is permitted, and the extinguisher must pass the procedure twice within a maximum of three attempts. The successful certification of Hydrogel across four portable extinguisher sizes establishes a performance benchmark for lithium-ion battery fire safety.
It also allows users to select an extinguisher size appropriate to applications ranging from consumer electronics to e-bikes and power tools.
NTA 8133 has provided an important basis for draft EN 3-11, the proposed European standard for portable extinguishers suitable for lithium-ion battery fires.
The standard is currently expected to be finalised in September 2026. Once adopted, it is expected to introduce harmonised European performance, testing and marking requirements, including use of the Class L designation in accordance with ISO 3941. Its scope concerns portable applications with limited battery capacity and does not validate extinguishers for electric-vehicle batteries or large stationary energy storage systems.
The future of lithium-ion battery fire safety
As electrification accelerates, lithium-ion batteries will become even more common in homes, transport, industry and critical infrastructure. The associated fire risks cannot be managed effectively by treating them as conventional fires.
Hydrogel reflects a materials-led approach to lithium-ion battery fire suppression.
By combining rapid cooling with persistent adhesion, physical containment, gas control and chemical stabilisation, it addresses the complete development of a lithium-ion battery incident. The result is not simply faster flame suppression, but a pathway towards safer and more sustainable fire control in an increasingly battery-powered world.
Anogas develops lithium-ion battery fire suppression technology
Lewis Tyler
Share this content
Anogas has developed Hydrogel, a PFAS-free extinguishing agent designed to improve lithium-ion battery fire suppression through rapid cooling, gas control and thermal stabilisation
Lithium-ion batteries power smartphones, laptops, e-bikes and electric vehicles, while large energy storage systems support the transition to renewable energy. Their high energy density and long life make them highly effective, but they also introduce a fire risk that conventional extinguishing methods were not designed to manage.
Anogas, a Dutch materials innovation company with more than 20 years of experience in advanced materials, has developed Hydrogel as a sustainable response to this growing challenge. Made primarily from water and modified natural clay, the extinguishing agent is PFAS-free and designed to control the thermal, physical and chemical processes involved in lithium-ion battery fires.
Understanding lithium-ion battery fire risks
A lithium-ion battery fire is driven by reactions inside the battery rather than by an external fuel source alone. Mechanical damage, overheating, manufacturing defects or improper charging can destabilise an individual cell.
As its internal temperature rises, the cell may enter thermal runaway: an accelerating reaction that generates more heat, breaks down internal materials and releases flammable gases. Pressure builds until the casing ruptures.
The resulting heat can then spread to neighbouring cells, creating a cascading chain reaction. A small failure can therefore develop into a major incident within minutes. The gases released create an additional hazard. Hydrogen and methane can ignite or explode, while hydrogen fluoride is toxic and corrosive.
Gas release may continue even after visible flames have disappeared, leaving a risk of delayed ignition or re-ignition. Successful intervention therefore requires more than simply knocking down the flames.
The battery must be cooled, escaping gases must be controlled and the system must be stabilised.
How Hydrogel improves battery fire suppression
Hydrogel combines several extinguishing mechanisms in one material. Its high-water content absorbs heat rapidly and cools the battery at the source. Unlike water alone, however, Hydrogel becomes more viscous when exposed to high temperatures.
This temperature-sensitive response allows it to adhere to hot surfaces instead of flowing away. The resulting layer maintains contact with the battery and provides sustained cooling. It also forms a physical barrier that restricts oxygen, separates escaping gases from ignition sources and helps limit heat transfer to adjacent cells.
This is particularly important because residual heat and chemical activity can persist long after the visible fire has been extinguished. The modified clay particles add a further stabilising effect.
They can enter damaged battery structures and interact with reactive components, helping to reduce the reactions that sustain the incident.
At the same time, the water-and-clay-based barrier can reduce the concentration and ignition potential of hazardous gases. Together, these effects address the fire from several directions: cooling, containment, gas control and chemical stabilisation.
Controlling thermal runaway and preventing re-ignition
Thermal runaway can produce temperatures of approximately 1,500 degrees Celsius.
At these temperatures, extinguishing the visible flames is only the first stage. The objective is to bring the battery to a stable state without propagation or re-ignition. Hydrogel remains stable at these high temperatures, adheres to the affected surface and continues absorbing heat after the initial flame knockdown.
This prolonged action distinguishes comprehensive fire control from temporary suppression.
The technology can be applied through handheld extinguishers, mobile equipment and fixed water-based systems.
When deployed in expanded form, it can also cover larger surfaces, adhere to vertical structures and improve contact with difficult-to-reach areas. The amount required depends on the size and accessibility of the battery.
Small consumer devices may be addressed with a compact extinguisher, while e-bikes, power tools and larger battery systems require greater quantities. Industrial installations may need fixed or high-capacity delivery systems capable of applying Hydrogel from a safe distance.
Applying Hydrogel and managing post-fire safety
During an intervention, the initial focus should be on extinguishing all visible flames and preventing the fire from spreading.
Hydrogel should then be directed towards the battery surface and, where possible, into the internal structure to achieve localised cooling. Application can be repeated when new flames or gas emissions appear.
The situation should be monitored until no visible flames return and audible signs of gas release, such as hissing or sizzling, have stopped. Responders must still keep a safe distance and use appropriate respiratory protection.
Hydrogel can reduce atmospheric hazards, but it cannot remove every toxic gas produced by a failing battery. After stabilisation, an observation period of at least 20 minutes is recommended. The affected battery should subsequently be isolated from combustible materials and placed in a suitable containment or cooling arrangement.
Continued monitoring and a cooling period before disposal remain essential because damaged cells can retain energy and heat.
PFAS-free fire suppression and environmental performance
Many traditional firefighting foams have relied on PFAS to improve spreading and thermal stability. These substances are highly persistent, can contaminate soil and groundwater and are increasingly restricted.
European regulation is moving towards a complete phaseout of PFAS-containing firefighting agents, increasing demand for effective alternatives. Hydrogel contains no detectable PFAS and is based largely on water and natural clay.
This allows Anogas to combine operational performance with a lower environmental burden. Residual material can be collected, while suitable unused material may be separated and its clay-based fraction explored for reuse as a compost enhancer, supporting a more circular lifecycle.
NTA 8133 certification for lithium-ion battery fire extinguishers
Independent testing is essential when an extinguishing agent is intended for lithium-ion battery fires. Hydrogel extinguishers in 2-, 3-, 6- and 9-litre formats have been successfully tested and certified by Kiwa in accordance with NTA 8133.
This Dutch Technical Agreement provides a standardised method for evaluating portable fire extinguishers intended for lithium-ion batteries with a limited capacity of up to 600 Wh.
During the test, a 600 Wh arrangement of lithium-ion pouch cells is deliberately forced into thermal runaway. The operator must control the fire within the prescribed extinguishing period, after which the test is observed for 20 minutes.
No sustained re-ignition is permitted, and the extinguisher must pass the procedure twice within a maximum of three attempts. The successful certification of Hydrogel across four portable extinguisher sizes establishes a performance benchmark for lithium-ion battery fire safety.
It also allows users to select an extinguisher size appropriate to applications ranging from consumer electronics to e-bikes and power tools.
NTA 8133 has provided an important basis for draft EN 3-11, the proposed European standard for portable extinguishers suitable for lithium-ion battery fires.
The standard is currently expected to be finalised in September 2026. Once adopted, it is expected to introduce harmonised European performance, testing and marking requirements, including use of the Class L designation in accordance with ISO 3941. Its scope concerns portable applications with limited battery capacity and does not validate extinguishers for electric-vehicle batteries or large stationary energy storage systems.
The future of lithium-ion battery fire safety
As electrification accelerates, lithium-ion batteries will become even more common in homes, transport, industry and critical infrastructure. The associated fire risks cannot be managed effectively by treating them as conventional fires.
Hydrogel reflects a materials-led approach to lithium-ion battery fire suppression.
By combining rapid cooling with persistent adhesion, physical containment, gas control and chemical stabilisation, it addresses the complete development of a lithium-ion battery incident. The result is not simply faster flame suppression, but a pathway towards safer and more sustainable fire control in an increasingly battery-powered world.
Newsletter
Receive the latest breaking news straight to your inbox
Post navigation
Latest Issue